VectorQ5

The VectorQ5 is a solid-state power controller. It measures all three phases at once and builds a model of what it measures. From that model it corrects power factor, harmonics, phase balance and impedance together, many times in every cycle of the sine wave, with at least 97% efficiency. Others say efficiency up to a number. We say at least 97%.

For 480-volt three-phase networks with neutral.

What is inside

Each step below names one part of the VectorQ5.

Mounting bracket

The unit mounts indoors, on a wall or on its optional stand.

Power router board

The power router board is the controller’s motherboard. It is high-voltage and optically isolated. It samples 26 parameters on every phase at once. Silicon carbide transistors sit on its liquid-cooled plate. Two air-cooled processors sit on the board as well.

Electrical modeling board

FPGAs, GPUs and processors on this board build a model of the electricity. The board processes over 1 TB of equivalent data per minute.

Correction board

The correction board computes the corrections that balance the electricity. It responds within a few microseconds. A microsecond is one millionth of a second (10⁻⁶, or 0.000001).

Channel boards

Three more boards sit on top of the stack, one per channel. Each carries its own processor on its own water block. They vectorize the data and give the controller redundancy.

Water cooling

A sealed liquid loop cools the processing and power components. Fixed tubing connects each water block to the loop. Two pumps drive the loop. The loop does not leak and needs no servicing.

Compliance filters and safety

The metal boxes around the boards are the compliance filters and the safety components.

Circuit breakers

The main power breaker sits on the front panel. A second breaker sits inside the unit.

Fans and status LEDs

Three exhaust fans sit in the right side panel. Three status LEDs on the front show the state of the unit.

Enclosure

The enclosure is powder-coated aluminum, rated IP20 and non-flammable. It measures 26 by 22 by 10 inches and weighs 160 lb.

Bottom connections

The power and current sensor connections sit under the unit. The supply cable carries three lines, one neutral and one ground.

Current transformers

Three split-core current transformers measure current up to 200 A per phase. The standard cable is 6 ft long, and other lengths are available on request. Each transformer is calibrated to its own controller and cannot be exchanged between units.

Supply breaker

A dedicated breaker in the panel feeds the controller. The supply cable runs in parallel with the electric network.

Panel installation

A qualified, licensed electrician does all the work. The controller mounts beside the panel, with conduit between them. The dedicated breaker goes into the panel, switched off. The three current transformers go on the incoming phase conductors, and their cables run in their own conduit. With the panel cover back on, the dedicated breaker turns on first, then the front breaker.

Running

The three LEDs show the state: green for power, blue for correction, red for an alert.

  • Blue steady on: correction active
  • Blue slow blink: self-test or delay before correction
  • Red fast blink: limiting parameter reached
  • Red steady on: network or device issue

Specifications

Electrical

ParameterVectorQ5
Operating Voltage3ϕ + N / 480 VAC
Voltage Tolerance±15%
System Frequency60 Hz (USA mainland)
Frequency Tolerance±0.5%
Correction Power RatingUp to 120 kW
Typical Power Consumption< 150W
Max Current / Phase60 A
Round-Trip Efficiency> 97% at full load
Connection to panel3L + 1N + 1G cable, Parallel to the electric network
CT Rating, included3 current transformers, rated to 200 A per phase max (call for custom)
CT Cable Length6 ft standard (other lengths on request)
Electrical Supply SystemTN-C/S

Correction

ParameterVectorQ5
Reactive Correction60 kVAR (20 kVAR/ϕ)
PF Correction Range±90° to Unity (capacitive & inductive)
Harmonic MeasurementDynamic, up to 53rd order
Harmonic CorrectionDynamic, up to 23rd order
THD Correction Target< 5% on all phases, real-time
Phase Load BalancingDynamic, within 20% of average
Neutral CurrentReduced to near zero via active phase balancing
Compensation Effectiveness> 97% harmonic reduction at rated capacity
Sensing Speed< 10 ns measurement resolution
Correction Response< 5 µs (microsecond regime)
PF & THD Sensing MethodFuzzy logic, dynamic, 1,000+ samples per sine wave
Operating ModesAutomatic: simultaneous PF + THD + balance + impedance matching
TopologyDigital solid-state, full-bridge per phase
Switching FrequencyAdaptive, DSP-controlled
Overload BehaviorCurrent-limited; automatic derating at thermal threshold
Parallel Unit CapabilityMultiple units; no master/slave configuration required
Surge ProtectionContinuous, non-degrading, unlimited events

Mechanical

ParameterVectorQ5
Dimensions (H × W × D)26 × 22 × 10 in
Weight160 lb (73 kg)
EnclosurePowder-coated aluminum, IP20, non-flammable
InstallationIndoor, Wall-mounted or standalone (optional stand)
Cooling MethodForced air (internal fans)
Heat Dissipation< 3.6 kW at full load
Noise Level< 65 dB(A) at 1 m

Environment and standards

ParameterVectorQ5
Operating Temp.23°F to 108°F (−5°C to +42°C)
Humidity85% max, non-condensing
Storage Temp.14°F to 158°F (−10°C to +70°C)
Max Altitude3,300 ft (1,000 m); consult factory for higher elevations
Pollution Degree2 (non-conductive pollution only)
Vibration Class3M1 (indoor use, per IEC 60068-2-6)
Applicable StandardIEC 62477-1:2012 + A1:2016 (PECS)
CE-LVD StandardEN 62477-1:2012/A1:2017/A12:2021
Harmonic StandardDesigned to meet IEEE 519-2022 at point of common coupling
Protective ClassII (double / reinforced insulation)
Overvoltage CategoryOVC II (300 V system voltage)
Impulse Withstand (Reinforced)4.0 kV
EMC ClassificationClass A (industrial / commercial environments)
Surge ClassificationClass B: continuous, non-degrading over time and events
Min Clearance (Air)1.5 mm (PD2, OVC II)
Safety CertificationCE conformity assessment per IEC 62477-1; UL field evaluation required
Country of OriginManufactured in USA (Pittsboro, NC) with global components

CE conformity assessment per IEC 62477-1. UL compliance by field evaluation.

Specifications subject to change. Custom voltages available upon request. Contact 3DFS for application engineering support.

The pilot program

Buying a VectorQ controller starts with a pilot, not a cart.

We help set up the pilot.

Back to Products

  • Baseline. Before the controller. The pilot opens with a baseline at the panel, before the controller goes in.
  • Cycling. Controller on and off. Next, the controller cycles on and off in turns. The instruments record the whole time.
  • Result. Set against the baseline. The pilot closes on an instrumented result, good or bad. That result names who measured it.