On July 10, 2024, a lightning arrester failed on a 230 kV transmission line in the Eastern Interconnection (NERC Incident Review, January 2025, p. 1). The line’s automatic reclosing turned that failure into six successive faults in an 82-second period. Each fault lasted 42 to 66 milliseconds (NERC, pp. 1 and 2). About 1,500 MW…
Category: Articles
-
-
A data hall trial measures what correction does on a site’s own load. It starts with one week of measurement at one PDU (3DFS data centers). That week is the baseline for the corrected readings, on the same load (3DFS Resilience). What a trial decides A trial decides one thing: whether the current measured at…
-
A 208Y/120 V branch circuit can carry three phases and a shared neutral to 120 V outlets in a rack (White Paper 38, p. 5). A published case study calls neutral oversizing of 170% to 200% an unnecessary cost (White Paper 38, p. 12). In the server room it measured, most neutral current came from…
-
Last updated: 2026-10-30 ERCOT’s NOGRR282 has been in effect since 2026-08-01 (ERCOT NOGRR282). The Public Utility Commission of Texas approved it on 2026-07-09. It adds two sections to the Nodal Operating Guide, 2.6.4 for frequency and 2.15 for voltage (PUCT report). Ride-through here means the load stays connected and keeps drawing power through a disturbance…
-
Military bases asked to run 90 days off the grid: what FORTRESS America says and what it takes electrically

The Pentagon is preparing major military bases in the continental United States to sustain essential operations on their own for at least 90 days, Fox News Digital reported on 25 October 2026 from documents it reviewed. The requirement sits under FORTRESS America, a program the Secretary of War established in a memo dated 30 September…
-
A data center that drops off the grid during a fault is now a regulatory matter in Texas, and national rules are on their way (ERCOT, FERC). Three rules changed in 2026. FERC ordered NERC on 2026-07-16 to file national standards for computational loads (FERC). ERCOT’s NOGRR282 has been in force since 2026-08-01 (ERCOT). NERC’s…
-
CLO-001-1, CLO-002-1 and CLO-003-1 are three NERC Reliability Standards for data centers and similar sites, adopted by NERC’s Board and awaiting FERC approval. They cover interconnection studies and modeling data (001), operating data and communications (002), and protection coordination and disturbance recording (003). Each applies to Computational Load Sites with a total load of 50…
-
Last updated: 2026-10-29 Computational loads are not subject to NERC Reliability Standards today (PJM Inside Lines, 2026-08-11). NERC’s Board adopted CLO-001-1, CLO-002-1 and CLO-003-1 on 2026-10-26, and NERC lists all three as pending regulatory filing (NERC One Stop Shop workbook, NERC newsroom, 2026-10-27). FERC set 2026-12-31 as the filing deadline (FERC order, Docket RD26-7-000). In…